check out the new remote control Jockey Wheel SmartBar rearview170 Beam Communications SatPhone Shop Topargee products Enginesaver Low Water Alarms
Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Hot water back flow


Guru

Status: Offline
Posts: 754
Date:
Hot water back flow


When connected to tap my water hose is blowing off after a couple of hours and hot water pours out( heater on electics). No Leakage internally and it doesn't happen on internal water or when the heater is on gas.
Any ideas anyone?


__________________

http://garykerrystraveldiary.blogspot.com/


htttp://garyandkerrys2009travels.blogspot.com.




Port Noarlunga SA

Experience is something you don't get until just after you need it.


Guru

Status: Offline
Posts: 588
Date:

Gary, not wishing to state the blooming obvious, its a pressure build up, as you will know, but why?

I will have a crack at an answer, and see if that helps

All HWS have a safety relief valve, to prevent over pressure from the heated water. This is normally set higher than mains pressure. I do not think it is this, but maybe check it operates.

When on tank water, any over pressure will be returned to the tank, so you would not notice this.

If I am right, on gas, the system heats to a certain point, but only cuts in to full, when in use, ie water flow, so again, you would not notice the problem.

So my conclusion is that on electric, it heats to full temp, and the pressure, while below the relief valve setting, is greater than the abilities of your fittings.

The answer may be a check (backflow) valve on the van, but only if the releif valve functions correctly.

Maybe someone with better knowledge has an answer



__________________
The devil made me do it - to hell with the Devil


Guru

Status: Offline
Posts: 754
Date:

twobob wrote:

Gary, not wishing to state the blooming obvious, its a pressure build up, as you will know, but why?

I will have a crack at an answer, and see if that helps

All HWS have a safety relief valve, to prevent over pressure from the heated water. This is normally set higher than mains pressure. I do not think it is this, but maybe check it operates.

When on tank water, any over pressure will be returned to the tank, so you would not notice this.

If I am right, on gas, the system heats to a certain point, but only cuts in to full, when in use, ie water flow, so again, you would not notice the problem.

So my conclusion is that on electric, it heats to full temp, and the pressure, while below the relief valve setting, is greater than the abilities of your fittings.

The answer may be a check (backflow) valve on the van, but only if the releif valve functions correctly.

Maybe someone with better knowledge has an answer



Thanks Bob,
I have had a closer look this morning , there is a one way valve between the HWS plumbing and the fill point and so i think this is probably be the culprit.
Will only turn HWS on just before use whilst connected to mains if i can't get a replacement before getting home.
We don't spend a lot of time in CP's so shouldn't be a major issue.


__________________

http://garykerrystraveldiary.blogspot.com/


htttp://garyandkerrys2009travels.blogspot.com.




Port Noarlunga SA

Experience is something you don't get until just after you need it.


Guru

Status: Offline
Posts: 6882
Date:

I have found if I only turn the main supply tap on about half flow and not flat out it doesn't blow off the connections.
Also make sure your connections are all firm. Brass has a longer life.
It's a bit of trial and error. Good luck with that. Cheers Chris


__________________

20ft Roma caravan - Mercedes Benz Sprinter - SA-based at the moment.
Transport has no borders.

Management makes the decisions, but is not affected by the decisions it makes.



Guru

Status: Offline
Posts: 2333
Date:

Has to be the non return valve..... Have you tried cold showers?
Have you checked the anode?

__________________
Don't take life too seriously.... No one gets out alive

KIA Sorento CRDi EX  ( Ebony black) with 5 hex chrome plated tire air valve covers, Coramal Sunsheild, Elcheapo GPS, First Aid Kit, full KIA toolkit & Yellow lenses on the Foglights......


Newbie

Status: Offline
Posts: 1
Date:

Ok most units have a relief valve that should drip some water as it heats up to relieve excessive pressure... .....make sure this is working by observing that water drops from the relief pipe.
But. . . .. your problem is the check valve in the piping

It wont be the anode. . ..that is only there to stop corrosion and rust.

__________________


Guru

Status: Offline
Posts: 2333
Date:

troublemaker wrote:

Ok most units have a relief valve that should drip some water as it heats up to relieve excessive pressure... .....make sure this is working by observing that water drops from the relief pipe.
But. . . .. your problem is the check valve in the piping

It wont be the anode. . ..that is only there to stop corrosion and rust.



Yes I meant have you checked the anode to make sure you still have some anode left, they get used up quickly.

 



__________________
Don't take life too seriously.... No one gets out alive

KIA Sorento CRDi EX  ( Ebony black) with 5 hex chrome plated tire air valve covers, Coramal Sunsheild, Elcheapo GPS, First Aid Kit, full KIA toolkit & Yellow lenses on the Foglights......
Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us
Purchase Grey Nomad bumper stickers Read our daily column, the Nomad News The Grey Nomad's Guidebook