Post Info TOPIC: Kipor diesel generator, starts then shuts off


Newbie

Status: Offline
Posts: 1
Date:
Kipor diesel generator, starts then shuts off


Hi,

Have a Kipor KDE 6700 diesel generator, bought it new about 5 years ago. It ran fine for awhile. Now when I try to start it, it starts but then shuts off immediately. Any suggestions on what may be the issue?



__________________


Senior Member

Status: Offline
Posts: 460
Date:

Hi It sounds like low oil ? Mine did that and thats what it turned out to be.. good luck ...Bob n Bev 



__________________

Land Rover Discovery Chipped TD5 Manual ,Air Springs, Anti Sway. T.C.
Auto level. Van, Roadstar 21.6 Voyager 4000 all sola powered.



Guru

Status: Offline
Posts: 2339
Date:

Around the crankcase of the engine there will be an low oil cut off switch, to see if it is faulty just remove the wire and tape it up, now try and start it. Could also be air in the fuel, have you changed the fuel filter recently?. Not much to go wrong with a simple diesel engine.
cheers
blaze

__________________
http://blaze-therese.blogspot.com/


Senior Member

Status: Offline
Posts: 146
Date:

Hi sailor - may I suggest that you post this in the Techies forum? You might get more replies from suitably qualified persons there :)

__________________


Not grey yet, but if I keep playing with campervans, I suspect that I very soon will be!



Guru

Status: Offline
Posts: 9575
Date:

Gday...

My Honda Genny fuel cap has an "on" and an "off" position... when it is "off" it cuts off the air flow into the tank (and fuel venting to atmosphere).

If it is in the "off" position when started ... it will only run for a minute or so and then cut out.

So, does yours have such a vented cap? ... if so, check which position it is in and make sure it is in the "on" position when you start it.

cheers

John



__________________

2006 Discovery 3 TDV6 SE Auto - 2008 23ft Golden Eagle Hunter
Some people feel the rain - the others just get wet - Bob Dylan



Guru

Status: Offline
Posts: 1970
Date:

Oh No! My Kipor died on me after 9 hours work at Greens Lake...It was put down too Carbon build up and cleaned The spark plug..was a mess.......The boys at Greens Lake helped me as best they could But I had to take it back to Shepparton for repairs......Must say I am worried down the track aout it happening again...After the twelve Months warranty runs out...Bunnings Shepparton watch out

__________________

  I always leave my camping area cleaner than I found it.



Guru

Status: Offline
Posts: 885
Date:

deleted, didn't note the diesel fuel.



-- Edited by johnq on Sunday 13th of November 2011 12:18:00 AM

__________________


Guru

Status: Offline
Posts: 2339
Date:

jimbo wrote:

Oh No! My Kipor died on me after 9 hours work at Greens Lake...It was put down too Carbon build up and cleaned The spark plug..was a mess.......The boys at Greens Lake helped me as best they could But I had to take it back to Shepparton for repairs......Must say I am worried down the track aout it happening again...After the twelve Months warranty runs out...Bunnings Shepparton watch out


 Jimbo

Once a week run your generator fully loaded for an hour or so. Plug a hairdryer or heater on it and work it hard, they will always carbon up if not worked hard

cheers

blaze



__________________
http://blaze-therese.blogspot.com/
gst


Senior Member

Status: Offline
Posts: 385
Date:

Sounds like it needs a good service.



__________________


Guru

Status: Offline
Posts: 1467
Date:

Homelite 7.JPGjimbo wrote:

Oh No! My Kipor died on me after 9 hours work at Greens Lake...It was put down too Carbon build up and cleaned The spark plug..was a mess.......The boys at Greens Lake helped me as best they could But I had to take it back to Shepparton for repairs......Must say I am worried down the track aout it happening again...After the twelve Months warranty runs out...Bunnings Shepparton watch out


 This was the result of running a Generator for long periods with a small load. It actualy got to a point of not being turned past TDC. The owner now runs a larger load after de carbonising. This was a Homelite 1100watt. I have a Kipor 2600Watt geny & it is always run with at least 500W load to avoid this hapening, its now about 4Yrs old .



__________________
D.L.Bishop


Guru

Status: Offline
Posts: 1467
Date:

KIPOR Inst.1.JPGThis was the instructions with my generator & i did exacly what it sugest to do. Run for 20 Hrs aprox with over 50% load. In my case a 1800Watt heater to bed the ring in. If you havent done this you can expect more trouble.



__________________
D.L.Bishop


Guru

Status: Offline
Posts: 3917
Date:

When I was gainfully (?) employed we had installations with diesel generators (usually around 35 KVA) that were run under load once a week for long enough for the unit to come up to operating temperature and to stabilise. They were fitted with time-out devices to prevent them shutting down early. In some cases "dummy" loads (oil bath cooled resistors) were needed to provide the test load. Daryl (DeBe) achieves the same with his 1800 watt heater.

 

PS: Welcome to the forum, I hope it gives you the information you need.  Just a hint, there is also a "Techies Corner" forum as part of this site where topics such as this tend to "last longer" and not get buried under new topics as quickly as here

cheers,

Jim



-- Edited by jimricho on Sunday 13th of November 2011 07:59:18 AM

__________________

Merda tauris scientia vincit