The system on our van is 3 x 145w solar panels coupled into a GSL mppt 60 amp regulator. I have wired the system up so that there is a removable jumper connection, made up of Anderson plugs. The reason I did this is two fold, one to easily disconnect the solar panels before working on the batteries, and to enable a portable panel to be connected into the series circuit when required.
I am of the understanding that all panels in the circuit should be the same wattage and voltage, if not the lowest rated panel will drag the rest of the system down do match. is that correct?
If so, the portable panel I purchase, should be at least 145w, I am looking at 160w, can't find one at 145w, is this OK.
Also if the above is correct, what happens when one panel is shaded, do all the panels get dragged down ?, so far the system has worked well, but as we are running a compressor fridge, any extra solar power is appreciated.
Thanks Ken, that page deals with parallel circuits, but that site also has the same article relating to series circuits, which I shall read, and my questions will most likely be addressed.
In series the Amps is what governs you so as long as it is a higher wattage it's fine, the amps will be limited by panel with the lowest amp rating, but in parallel it's the voltage to watch so to connect 3 at 145w and 1 at 160w in series this is fine as the voltage is added. In parallel the amps are added but limited to the panel with the lower volts.
One thing to check before adding more panels in series is that the controller can handle the voltage.
This guy has 145w panels https://sbpe.com.au/collections/solar-panels-rigid-solar-panels I bought 2 a few weeks ago and they tested up to spec no problems if you scroll down the page a bit they have ones that were restocked for $79 these are what I bought
OK I have read and digested the tutorial on "Series Connected Panels", and that the system power is reduced in efficiency by the lowest wattage panel. My question now is, in the circuit, mine for instance 3 x 145 panels, if one (or two ) is partially shaded, will that panel now produce less amperage, and therefore lower the efficiency of the whole system?
In other words for a series system there must be no shaded panels.
>My question now is, in the circuit, mine for instance 3 x 145 panels, if one (or two ) is partially shaded, will that panel now produce less amperage, and therefore lower the efficiency of the whole system?
If you are describing 3 x 145W in series... then yes.
>In other words for a series system there must be no shaded panels.
Ideally, yes. The "string" of panels will still work but will be restricted to the efficiency of the most shaded panel.
__________________
"I beseech you in the bowels of Christ think it possible you may be mistaken"
Oliver Cromwell, 3rd August 1650 - in a letter to the General Assembly of the Kirk of Scotland
>My question now is, in the circuit, mine for instance 3 x 145 panels, if one (or two ) is partially shaded, will that panel now produce less amperage, and therefore lower the efficiency of the whole system?
If you are describing 3 x 145W in series... then yes.
>In other words for a series system there must be no shaded panels.
Ideally, yes. The "string" of panels will still work but will be restricted to the efficiency of the most shaded panel.
Hi iana
Haven't we been here before ??
It you have panels in series then you do need bypass diodes to bypass shaded panels. Obviously if you have 2 out of three shaded then you get 1 panel output but it still works.
Initially the system was three panels in parallel, but on the advice of a solar installer, and having obtained an MPPT regulator, the system was changed to series. In the parallel configuration, all the panels had by-pass diodes. When I converted it to series, and at that stage we were in a caravan park, I got confused over bypass diodes, and so I left some out of the system. Overall it seems to be working OK, so regarding panels not working in shade that confuses me as mine do work.
Obviously a parallel system is much less complicated if thinking about plugging in a portable panel, which is what my initial question really was. So Jaahn, yes I have many moons ago chatted about this, only to come away confused. Tony supplied me with the bypass diodes, thankyou.
Hi John.It's a long and complicated explanation,but if you simply Google "Solar panel optimisers" all will be revealed.All panels in a string of solar panels will only work at the same rate as the worst performing panel,but optimisers remedy that.Brief explanation.Cheers
If diodes are so important when a shadow is over a string of cells, why is it that the panel suppliers are reluctant to say how many diodes are used, and why are two normally used instead of say 4 or more ?
If diodes are so important when a shadow is over a string of cells, why is it that the panel suppliers are reluctant to say how many diodes are used, and why are two normally used instead of say 4 or more ?
I have a couple of old 87w Kyocera panels that were on lights in a caravan park for a long time. They have 3x 3 diodes in the junction box from new. I am not sure why so many.
Hi Yobarr Good question but what are they ?? Jaahn
Hi John.It's a long and complicated explanation,but if you simply Google "Solar panel optimisers" all will be revealed.All panels in a string of solar panels will only work at the same rate as the worst performing panel,but optimisers remedy that.Brief explanation.Cheers
Yobarr I did google them. I will look further but It seems to me two things !
1 they are mostly aimed at ac grid connect systems. Even id dc types. Not sure how that fits with mobile use.
2 If they give a small % improvement, even say 20% then at the high initial extra cost, you would generally be better off just buying another panel or two. That may not suit some applications.
Hi Yobarr Good question but what are they ?? Jaahn
Hi John.It's a long and complicated explanation,but if you simply Google "Solar panel optimisers" all will be revealed.All panels in a string of solar panels will only work at the same rate as the worst performing panel,but optimisers remedy that.Brief explanation.Cheers
Yobarr I did google them. I will look further but It seems to me two things !
1 they are mostly aimed at ac grid connect systems. Even id dc types. Not sure how that fits with mobile use.
2 If they give a small % improvement, even say 20% then at the high initial extra cost, you would generally be better off just buying another panel or two. That may not suit some applications.
You've done well John! As you have discovered,they are particularly useful in AC grid connect situations,but your suggested solution of " buying another panel or two" is not often possible in a real life AC situation because all such connections have input restrictions.For example,the biggest system you can have on a "normal" single phase house is 6.6kw through a 5kw inverter,so if you're already at your maximum panel capacity,adding more panels is not an option.There are ways around this,but I will not "rock the boat" by saying more.Suffice to say,optimisers are a life-saver for many tricky installs,and more than compensate for added expenditure at install.Cheers