Quick battery disconnect inside and close by


I am surprised that vans/RV's don't have to have a quick disconnect switch

to disable the batteries when they are either overheating or worse, beginning to

burn up.

 

Compulsory on a boat, but in a van where the batteries could be difficult to

access (maybe under the bed) there's no way to quickly shut down a miscreant battery

before it's too late.

 

The scooters demonstrate how quickly it can happen.



__________________

If you are silent when terrorists murder Israelis, stay silent when Israel defends itself.

The war could end tomorrow - release the hostages and Hamas surrender.



Guru

Status: Offline
Posts: 7314
Date:

It would be a very good safety feature. Also from an inverter issue, let alone batteries themselves.

 

I carry a pair of parrot cutters, but usually not in a readily accessible location. I might rethink location.



__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Senior Member

Status: Offline
Posts: 430
Date:

The regs do have a requirement for automatic disconnection of supply in the case of a fault:-

Clause 5.4.7.1 Protection Device: Batteries and associated wiring shall be protected against overload and short circuit by means of fuses or circuit breakers in each unearthed pole. Protection devices shall be accessible, protected against accidental damage, and installed in one of the following locations- a) within 200mm of the battery terminals, or b) directly outside the battery compartment, or c) 1m from the battery terminals, provided each conductor is contained within a protective covering such as sheathing, conduit, or cable trunking for its entire length from battery terminals to the circuit protection device

Meanwhile a switch is usually for isolation, ie to disconnect the batteries for storage or servicing, not to protect in event of a fault. 

It is of course good practice to have both.

Note also that it says that protection device should be in "each unearthed pole" so that means in an isolated system (as in most caravans), there should be a fuse/circuit breaker in both positive and negative battery cables.



__________________


Senior Member

Status: Offline
Posts: 469
Date:

The Li ion batteries in scooters, phones etc. are a different chemistry to the LiFePO4 that we use.  There has never been a fire with LiFePO4 but they can swell up and vent nasty substances when over charged or over discharged but to get to that stage you will have needed a failure in your BMS and/or a failure in your charger, whether it be a dc to dc charger or a solar controller.

https://www.youtube.com/watch?v=yiOljillLRY

This second video has no relevance and a word of warning Please do not try this.  no

https://www.youtube.com/watch?v=07BS6QY3wI8

LiFePO4 is very safe smile.

 



__________________


Guru

Status: Offline
Posts: 7640
Date:

By old bus / motorhome had a 50mm piece of lead as a fuse off the main supply . 50mm long X20mm I guess 4mm thick . Fuso. Older vehicles had a disable wire we wouldnt really know it was a protection wire, fuse .

__________________
Whats out there


Guru

Status: Online
Posts: 583
Date:

An over-temperature warning device might also be helpful in detecting
rising temperatures in the batts in time to avert a tragedy.

__________________

If you are silent when terrorists murder Israelis, stay silent when Israel defends itself.

The war could end tomorrow - release the hostages and Hamas surrender.



Senior Member

Status: Offline
Posts: 430
Date:

Brodie Allen wrote:

An over-temperature warning device might also be helpful in detecting
rising temperatures in the batts in time to avert a tragedy.


 If you're talking about Lithium, then the regulations require not just a warning device, but also automatic disconnection of the battery...

Clause 5.4.12.3 Lithium Ion Batteries, Battery Safety System: Each lithium ion battery pack shall be protected with a battery management safety system either integrated into a battery pack or as a separate component. The battery management safety system shall continuously monitor the voltage, current and temperature of the battery and protect against the following by automatic disconnection - a) over and under voltage, and b) over and under temperature, and c) over current 

These functions are usually performed by the Lithium battery's BMS. Lead acid batteries have no such requirements.

Of course, having it in the regulations is one thing, people following the regulations is quite another. It doesn't help that the electrical regulations tend to lag the technology available by a good few years, and new rules are not applied retrospectively.



-- Edited by Mamil on Wednesday 15th of February 2023 08:03:20 PM