Hello chaps,
My apologies for my delay in getting back to you.
So I do not have continuity between the REG GND and pin c. I am getting 12v at pin c when the board is powered up by 12v. The only pin with continuity to the REG GND is the middle pin on the MOSFET.
not too sure where to go next.
Regards
Chris
Try running a small lead from the Reg middle pin to a separate known ground (neg) point. If the middle pin on a 3 term reg isnt grounded then they dont work, usualy the voltage will be too high on the 5V side.
Just tried that then and it sparked. I tried earthing out on the negative post on the danfoss board also tried on the negative post of the battery. All 3 pins of the mosfet seem to have 12v.
Ok so I tried providing a separate earth to the reg and still no change. I removed the reg and tested it on the bench and worked as it should. I resoldered the reg back to the board but only the 12v and 5v pins and kept the negative pin out and ran its own separate earth not through that board but back to the negative on the danfoss 12v supply and still no good. I started to disconnect plugs just out of curiosity. Once I disconnected the cable for the display the reg worked as it should. 12v on one side and 5v on the other. Is it safe to assume something on the display board has failed or corrupting the other board?
Hi I know this is a very old post, but hopefully someone is still around. I have this exact problem with my Waeco coolfreeze cf50. It runs on 240v. However, when I switch over to 12v it comes on for 2seconds, then the display cuts out and the compressor doesn't kick in. I have done the above, ie, connected to 12v, checked for 12v reaching the unit, bridged c+t, the compressor kicks in and the fridge runs. Although the display shows a continuous error light and the display half cuts out. I have 12v and 5v across the two points mentioned above. This is how the display looks while running with c+t bridged......
The [power light flashes once every 4 seconds
-- Edited by jameswrowe on Monday 5th of July 2021 07:02:43 PM
-- Edited by jameswrowe on Monday 5th of July 2021 07:34:05 PM
I am asuming your compressor controler is a Danfoss 101N0500 as in picture? When operating on 12V is there 12V on pin A+ & C-- ? There should be voltage there even when the compressor is not running as this power for the display/control board.
DeBe You are to be commended on the way that you have helped Crusa and the others. You obviously know what you are talking about. A special mention must go to those on here who refrained from offering "advice" and let you do your stuff.
These sort of posts are what forums like this do best, such a change from the bickering and playground name calling that some posts degenerate into.
__________________
Those who wish to reap the blessings of freedom must, as men, endure the fatigue of defending it.
DeBe You are to be commended on the way that you have helped Crusa and the others. You obviously know what you are talking about. A special mention must go to those on here who refrained from offering "advice" and let you do your stuff.
These sort of posts are what forums like this do best, such a change from the bickering and playground name calling that some posts degenerate into.