Has anyone got and set up one of these monitors?
They are available under different brand names...mine is a BEP.
I did a RESET and then SETUP & PROGRAMMING. Don't get an Amps input or output reading, only 0.Amps.
Instructions mention after reset it needs a DC 10amp load calibration.
So, how would you achieve a 10amp DC load?
All wiring & connections appear correct including the SHUNT.
Any suggestions welcome.
Cheers, Richard (Dick0)
"Home is where the Den is parked, Designer Orchid Special towed by Jeep Grand Cherokee Limited"
"4x250W solar panels, Epever 80A charger and 3x135Ah Voltax Prismatic LiFePO4 Batteries".
There are only three possibilities that it will not show some charge or discharge current if there is actually a current flow to or from your battery.
How many wires do you have connected to the negative terminal of the battery?
PeterDNissan Navara D23 diesel auto, Spaceland pop-topRetired radio and electronics technician.NSW Central Coast.
Thanks, located the problem after closer inspection.
Shunt was not connected through the Battery Negative at all. Why? Who knows...poor installer perhaps.
Relocated Shunt near battery and redirected Battery Negative through Shunt...all good now.
Rather careless on my part to not have noticed that. Had assumed that installation was correct in the first instance.