Fitting 600 watt sinewave inverter


Hi all.

I have a 600 watt sinewave inverter which I want to connect to my deepcycle batteries instead of using clip ons. Pictures attached.

 

What size fuse and cable to do recommend?

I've just been to Jaycar and they wasn't sure.

 

Any help appreciated.

 

Have a great day 

 

Troy



Attachments
__________________
T A Dear


Guru

Status: Offline
Posts: 1947
Date:

Hi Troybiggrin

Good idea to ask first biggrin My immediate answer would make the cable twice the copper size of the one supplied.  If you run it up to peak capacity of 600W then it will draw about 50 amps+ or even more if you use extra starting current it will supply(<100A @1200W). So the fuse needs to be bigger than expected use. But the fuse protects the wires from danger so that is important to note, (the inverter will protect itself OK). So the fuse is related to the wire rating.

What will you use it for ? If you just want to use say up to 100-150W or so charging things then OK the supplied wires might work well enough. But sometimes you might plug in a hair drier or an item which might draw a lot more. Then the voltage drop will cause the inverter to trip out or complain by beeping at you as the voltage gets low. Think about usage. 

Where will it be mounted ? Near the battery, best, but probably not handy for you to switch on and off and plug into it. Move it to a better place will need need a bigger size of wire if it is far. But you might find it is much handier to use. So how long will the cable run be.( X2 as it has to come and go).

Others may suggest what they did and their useage and comment.

Cheers Jaahn   



__________________


Guru

Status: Offline
Posts: 7579
Date:

As said above, how long is the cable run & as said X2, if it is 3 metres, it is actually 6 metres + & -

So measure carefully & allow room to manoeuvre at both ends.

4awg cable 6 metres (3m positive & 3m negative) your percentage loss is about 2%. Also do good quality ends so you don't get any resistance where the wire connects to the lug.

A nice thick wire will also act as a heat sink & draw heat away from the connector which is not a bad thing either.



__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Veteran Member

Status: Offline
Posts: 35
Date:

Thanks for your replies. Greatly appreciated. Have a great day. Troy

__________________
T A Dear


Senior Member

Status: Offline
Posts: 215
Date:

Whenarewethere wrote:

....

A nice thick wire will also act as a heat sink & draw heat away from the connector which is not a bad thing either.


 EEEK. There should be NO heat at the connector and if there is it means simply that the connector isn't up to the job. Get a connector with much more suitable ratings.

A 50A Anderson plug is NOT suitable for a 1000W inverter. Any fuse / circuit breaker in the system must be rated at the maximum to trip/blow at the rating of the weakest link. eg. If you're using the common 50A Anderson plug and suitable cable then the circiuit breaker / fuse should be rated to have tripped/blown BEFORE 50A is reached. 40A would be a good safe value.

A fuse or circuit breaker is there to protect the wiring and therefore will guard against fire but only IF it is rated correctly.



-- Edited by markf on Wednesday 22nd of April 2020 10:50:00 AM

__________________

Cheers,

Mark F...

VK3KW

Land Rover 2002 Discovery 2 Auto Td5

2010 Outback Campers Sturt

http://jandmf.com



Guru

Status: Offline
Posts: 7579
Date:

A 50 amp Anderson can have up 120 amp with 6awg & not hot plugged. Ie turned off before disconnecting.



__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Senior Member

Status: Offline
Posts: 215
Date:

Whenarewethere wrote:

A 50 amp Anderson can have up 120 amp with 6awg & not hot plugged. Ie turned off before disconnecting.


Yep, in a UL 1977 compliant installation. 6AWG cable and crimped. As far as I recall soldered is not UL 1977 compliant.

I'm 99% certain but I'm sure someone with access to the actual UL 1977 standard will correct me if I'm wrong.

The real issue though, is the notion of heat at the connector which just shouldn't happen at all.



__________________

Cheers,

Mark F...

VK3KW

Land Rover 2002 Discovery 2 Auto Td5

2010 Outback Campers Sturt

http://jandmf.com



Guru

Status: Offline
Posts: 7642
Date:

Fit inverter close as possible to batteries . 240v. Can run the distance . Keep in mind theres no safety RCD etc .

__________________