I just use the low-tech solution of connecting the Alternator output using Andersen Plugs, straight to my 3way fridge switched to 12v.
It has never worked as well.
The Solar remains connected to the DC DC Charger & house battery.
I do have the alternate option of plugging the Alternator into the DC DC charger if necessary, but then I have no 12v fridge connection. I could use the fridge on Gas but people say that's a no no while traveling!
That is a good idea, so thanks for that information
I have a Renogy DC/DC 12V 50Amp Battery Charger with MPPT
It prioritises the solar panels to charge the house batteries first, saving some wear and tear of the alternator
If the battery is so run down that it requires the full 50 amps of charging, it will take power from both solar and alternator
As I normally do long road trips, (you have to from the west coast), I have a manual circuit breaker between the alternator and Renogy charger, which I switch off
This gives me peace of mind, that the house section is completely isolated from the engine battery, as 500 Watt of roof solar is more than I need for my 12 VDC compressor fridge
As I also normally have my motorhome laid up for long periods of time, I have another manual circuit breaker between the solar and Renogy charger
I find with lithium batteries (when parked up), I just switch the solar on for one day each couple of months, then switch the solar off
You could feed the alternator into a 12 to 24 DC-DC converter, then into a MPPT & have a second identical model MPPT from the solar panels. Set the voltage for the MPPT from the alternator to a whisker below the solar panel MPPT voltage so it is charging first.
__________________
Procrastination, mankind's greatest labour saving device!
50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.
This seems an overly complicated solution. Simply disconnect the alternator feed from the solar controller by means of a switch or relay when not needed.
This seems an overly complicated solution. Simply disconnect the alternator feed from the solar controller by means of a switch or relay when not needed.
Alan
There are a lot of solutions available, some requiring physical intervention like mine.
I did what you suggest but rather than installing a switch and I did look briefly at a rotary switch that would do the job, because I had a few spare Anderson plugs I just used that option.
I have a mate who is heavily into electronics & I'm sure that he would have come up with a hi-tech solution.
In the end I suppose that we will each choose a solution that suits our situation.